HFAD

Features

  • Ultra-thin photoelectric smoke alarm device
  • Big button for hushing
  • Ten years battery service life
  • Self-test function
  • Simple to install
  • Ambient Light detection function
  • Certification to EN14604:2005/AC-2008
  • VDS 3131, CE Certified

Technical Specifications

  • Model Number:GS546
  • Power Source: DC 3V Built-in lithium battery
  • Quiescent Current: < 10uA
  • Alarm Sensitivity: 0.1-0.15 dB/m
  • Alarm Current < 90mA
  • Alarm Volume: > 85dB(A) @ 3m
  • Hush Time: 10 minutes± 10%
  • Battery Service Life: 10 years (approx)
  • Humidity Range: <95% relative humidity (RH)
  • Temperature Range: 0°C to 40°C
  • Size: 115mm diameter x 23.5mm depth

Functions

  • Standby: In the operating mode, the red LED will flash once every 40 seconds.
  • Alarm: When the smoke detector detects particles of combustion and the concentration of smoke reaches the alarm threshold, the red LED will flash once per second with a pulsating alarm. This alarm will persist until the smoke within the chamber is cleared or when the alarm is manually acknowledged.
  • Self-Test Function: It comes with self-testing function that can replace the manual weekly test.(Owners are recommended to test manually at least once a year)
  • Low Battery: When the battery voltage is below the set threshold, an intermittent chirp will be emitted and the red LED will flash ONCE every 40 seconds.
  • Sensor Chamber Fault: If the smoke detection chamber function weakens to below set threshold, a chirp signaling a fault will be emitted. Under this condition, the LED indication will NOT blink.
  • Buzzer Failure Fault: In the event of Buzzer failure, the red LED will have TWO flashes every 40 seconds
  • Silence: To silence the detector when it is in an alarm condition, pressing the test button will pause the alarm for approximately 10 minutes. Under this condition, the red LED will flash once every 8 seconds. If the smoke in the chamber is still present, the alarm will resound upon expiry of the silence mode.
  • Do Not Disturb (Hush): When the detector is in a fault or low battery mode, pressing the test button will temporarily silence this warning tone for 10 hours. However, the warning signal will resound after 10 hours if the detector is not being attended to. The red LED will flash once every 40 seconds under hush mode.

Home Fire Alarm Device (HFAD) - "Siterwell" GS546

Download PDF

Reliable Home Safety

From Honeywell

XS100 Smoke Alarm

XS100

  • Easy to Install & Use
  • Long life, Discreet Design
  • Approved by HDB for use in residential flats

Features

  • Detection Principle – Optical
  • Clearly visible LEDs : Normal, Fault, Alarm
  • Loud 85dB audible alarm
  • Large button - can be pressed with a broom stick
  • Hush Alarm
  • Fault Alarm
  • Automatic self-checks
  • Dirt compensation
  • Sealed in battery lasts for 10 years
  • Low profile design blends into ceiling
  • On/Off only by installing/removing from mounting plate
  • Approved to CE EN 14604:2005/AC:2008

Honeywell video edited to show mounting and removal from base.

Refer to user guide for complete information on device workings.

Installation

Mounting and Activation / Deactivation

X-Series smoke alarms don't need wiring at the point of installation; simply install the mounting plate first using supplied plugs and screws, then slide the alarm onto it to activate the alarm. X-Series smoke alarms can either be mounted on the ceiling or on walls.